Cardiac Science Powerheart G3 Intellisense Lithium Battery:
:.
..
Cardiac Science Powerheart G3 Intellisense Lithium Battery w/ 4-year warranty. Use in G3 9300E, 9300A, 9390E, and 9390A devices made after April 12, 2004. This Intellisense Lithium Battery 9146-202 is for use in yellow colored Powerheart® AED.
The first date shown is the "Install By" date, the second date on the battery represents the "Discard By" date. If you count back 5 years from the first date on the battery, that is the date the battery was manufactured.
Battery is Not Rechargeable. Do not attempt to recharge the battery. Any attempt to recharge the battery may result in an explosion or fire hazard.
Lithium Sulfur Dioxide Battery
Pressurized contents: never recharge, short circuit, puncture, deform, or expose to temperatures above 65°C (149°F). Remove the battery when discharged.
Battery Disposal
Recycle or dispose of the lithium battery in accordance with all federal, state and local laws. To avoid fire and explosion hazard, do not burn or incinerate the battery.
Caution: With the battery removed, such as during shipping or transport, the AED is unable to perform self-tests or rescues.
The Cardiac Science IntelliSense battery technology offers you the most advanced battery capabilities available for defibrillators. Cardiac Science IntelliSense batteries contain an integrated memory chip that automatically stores important usage information, enabling the battery to maintain a complete history of its operating life. The actual battery history can be reviewed using the RescueLink software.
This history includes:
• Battery Identification
• Battery Type
• Original Date of Installation in an AED
• Number of Charges completed
• Time in Operation (hours:minutes)
• Days of Standby Operation
• Battery Capacity Remaining
Cardiac Science Powerheart G3 Nonrechargeable AED Battery Yellow 9146-202
The battery operating life depends on the type of battery, actual usage and environmental factors.
The following table represents the expected life of the Powerheart AED when used in Standby Mode.
Full Operational
Estimated Shelf Life Replacement Guarantee
Model (from date of manufacture) (from date of installation) Typical Shocks
9146 Lithium 5 Years 4 Years up to 290 shocks
page
BATTERY SHELF LIFE
The Cardiac Science AED batteries have a shelf life of five years. Shelf life is defined as the length of time a
battery can be stored, prior to installation into AED, without degrading its performance.
Note: Storing the battery outside its specific range (0-50°C) will decrease battery life.
BATTERY INSTALLATION
1. With the label on the battery facing the AED battery compartment, insert the battery as shown in the drawing.
2. Push the latched end of the battery firmly into the AED, as shown in the drawing, until the battery snaps into place. The exposed side of the battery should be flush with the outside of the AED case.
3. Open the lid for 5 seconds to initiate a self-test. If the battery is installed properly, the
SMARTGAUGE battery indicator LEDs will illuminate and the STATUS INDICATOR will turn
GREEN. If service is required, then the SERVICE indicator will illuminate; call for service.
WARNING: Battery is Not Rechargeable. Do not attempt to recharge the battery. Any attempt to recharge the battery may result in an explosion or fire hazard.
CAUTION: Lithium Sulfur Dioxide Battery
Pressurized contents: never recharge, short circuit, puncture, deform, or expose to temperatures
above 65°C (149°F). Remove the battery when discharged.
CAUTION: Battery Disposal
Recycle or dispose of the lithium battery in accordance with all federal, state and local laws. To
avoid fire and explosion hazard, do not burn or incinerate the battery.
CAUTION: Use only Cardiac Science Approved Equipment
Using batteries, pads, cables, or optional equipment other than those approved by
Cardiac Science may cause the AED to function improperly during a rescue.
CAUTION: Possible Improper AED Performance
Using pads that are damaged or expired may result in improper AED performance.
© 2006 Cardiac Science Corp. All rights reserved. 112-2025-305 Rev A page 25
Section 3 - Getting Started
|
Associated Items:▼
|

Cardiac Science Powerheart Adult Defibrillation Electrode Pads 9131-001
Cardiac Science Powerheart Adult Defibrillation
Electrode Pads 9131-001 :
:.
..
Getting Started: Cardiac Science Powerheart Adult Defibrillation Electrode Pads come in a ready-to-use, sealed package containing
one pair of self-adhesive pads with an attached cable and connector. The
pads are disposable and should be discarded after each rescue.
The pads have a limited shelf life and should not be used beyond the
expiration date. Keep a fresh, unopened pair of pads plugged into the AED
at all times. Refer to the pad package label for operation temperatures.
An audible and visual alert will indicate after the self-test if the pads are missing, unplugged or damaged.
PAD INSTALLATION
1. Open the lid of the Cardiac Science Powerheart G3 AED.
2. Place the pad package into the lid so that the expiration label is visible through the
clear window on the lid. The expiration date of the pads will then be readable
without opening the lid of the AED.
3. Match the color of the connectors (red to red), then plug the pad connector into the
AED case. Once the pad connector is plugged into AED, the PAD indicator should extinguish.
4. Tuck the excess cable length in the bottom holder. With the pad package completely secured to the AED lid, close the lid.
5. Make sure the expiration date is visible through the clear window of the lid and check
to make sure that the STATUS INDICATOR is GREEN. If the pads are not installed
properly, the STATUS INDICATOR will be RED; call Customer Service for assistance.
CAUTION: Use only Cardiac Science Approved Equipment
Using batteries, pads, cables, or optional equipment other than those approved by
Cardiac Science may cause the AED to function improperly during a rescue.
CAUTION: Possible Improper AED Performance
Using pads that are damaged or expired may result in improper AED performance.
DIRECTIONS FOR USE:
1. Do NOT open until ready to use, short term use only.
2. Ensure the skin site is clean and dry.
3. Separate one pad from liner.
4. Place one pad on skin in either location.
5. Peel and place remaining pad.
STEP 1: ASSESSMENT AND PAD PLACEMENT
PREPARATION
Determine that the patient is over 8 years of age or weighs more than 55 pounds (25 kg) and exhibits
the following:
The patient is unresponsive, and
the patient is not breathing.
Remove clothing from the patient’s chest. Ensure the skin site is clean and dry. Dry the patient’s chest and
shave excessive hair if necessary.
Open the AED lid and wait until the LEDs are lit.
Note: When the patient is a child under 8 years of age or weighs less than 55 lbs (25kg), the
AED should be used with the Model 9730 Pediatric Attenuated Defibrillation Pads. Therapy
should not be delayed to determine the patient’s exact age or weight. See the directions for use
accompanying pediatric pads for procedure on changing adult pads to pediatric.
PLACE PADS
The AED will issue the prompt “Tear Open Package and Remove Pads.” Keep the pads connected to the
AED, tear the pad package along the dotted line and remove the pads from the package. Leave the package
attached to the pad wires.
After the prompt “Peel One Pad From Plastic Liner,” with a firm, steady
pull, carefully peel one pad away from the plastic liner.
Then, after the prompt “Place One Pad on Bare Upper Chest,” place the
pad with the sticky side of on the patient’s skin on the upper right chest,
placing the top of the pad on the collarbone. Avoid placing the pad
directly over the sternum.
Finally, after the prompt “Peel Second Pad and Place on Bare Lower Chest
As Shown,” pull the second pad from the plastic liner and place it on
the lower left chest, below and left of the breast.
Note: Cardiac Science’s defibrillation pads are non-polarized and can be placed in
either position as shown on the pad package.
When the pads are placed, the voice prompt will say “Do not touch patient. Analyzing Rhythm.” If the pads are
not properly placed or become disconnected at any time during the rescue, the voice prompt “Check Pads”
will be heard. When this occurs, ensure that:
Pads are firmly placed on clean, dry skin
Pad cable is securely plugged into the
AED.
|
|

Cardiac Science Powerheart AED G3 Pediatric Electrode Pads 9730-002
Free
Shipping
Cardiac Science Powerheart AED Pediatric Pads::.
..
Cardiac Science Pediatric Defibrillation Electrode Pads 9730-002 should be used when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight. See the directions for use accompanying Pediatric Defibrillation Electrode Pads # 9730-002 for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|
|

Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001
Free
Shipping
Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001::.
..
These infant / child reusable training defibrillation pads allow you to simulate hands-on pediatric rescue scenarios with the Powerheart G3. Pediatric Training Defibrillation Pads 9725-001 are intended for use with Cardiac Science AED training device to simulate and practice a real-life rescue scenario.
These are intended for use with with Powerheart® AED G3 Trainer.
Cardiac Science Pediatric, infant / child Training
Electrode Pads, teach how to use the
defibrillation pads when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight
when performing a real-life rescue. See the directions for use accompanying Pediatric Defibrillation Electrode Pads for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|
AED ProfessionalsTM General Medical Devices, Inc. Company Corporate Office: 348
W. Colfax Street, Palatine IL 60067
Phone: 1-847-202-3858
Fax: 1-866-879-7795 Toll Free: 1-888-541-2337
Copyright © 2004 - 2010 All rights
of design and text reserved
AED
Professionals is AED and AED Accessories Wholesale and Retail Store
of Super Defibrillator Values
AED Professionalsè
Copy Righted: ©Quick-Start
Package
AED ProfessionalsèCopy
Righted: ©Quick-Start
Essentials
Package
| |
|