 HeartSine Samaritan Pad Adult Pad-Pak Integrated battery & electrode System - Product Image

HeartSine Samaritan Pad Adult Pad-Pak Integrated battery & electrode System

HeartSine Samaritan Pad Adult Pad-Pak Integrated battery & electrode System
Original Replacement New Adult Heartsine Samaritan Pad-Pak cartridge: Heartsine samaritan PAD-PAK Combined Electrode and Battery Cartridge integrated unit is gray in color and is intended to be used with suspected victims of SCA for patients age 8 years to adult and weighing >25 kg/55 lbs.

Only one expiry date to monitor. Replacement of the battery and defibrillation pack must be carried out if the expiry date of the Pad-Pak(TM) has been exceeded. If the status indicator on the samaritan® PAD is not flashing you may need to replace the Pad-Pak(TM). For diagnosis of the reason for the status indicator not flashing, please refer to the troubleshooting section of your owner's manual.


Adult Electrodes (Pad-Pak-01) HeartSine samaritan PAD-PAK adult cartridge comes complete with battery and electrode pads as one integrated unit. Cartridge typically has a shelf-life of 3.5 years from date of manufacture, offering significant savings over other defibrillators that require separate battery and pad units.

WHEN TO REPLACE THE PAD-PAK(TM): The battery lifetime in use can be up to 6 hours monitoring or 30 shocks or a combination of both. A Pad-Pak(TM) in the stand by mode (inserted into the samaritan® PAD) has a shelf-life indicated by the expiration date (typically years from manufacture). Replacement < of the battery and defibrillation pack must be carried out if: the expiry date of the Pad-Pak > has been exceeded the Pad-Pak has been used ( is a single use item) it must be replaced with a new Pad-Pak (TM) cartridge. If the status indicator on the samaritan® PAD is not flashing you may need to replace the Pad-Pak Fo. r diagnosis of the reason for the status indicator not flashing please refer to the troubleshooting section of this manual. Maintenance Replacing The Pad-Pak The battery lifetime in use can be up to 6 hours monitoring, 60 shocks or a combination of both. A Pad-Pak in stand by mode (inserted into the SAM 300P) has a shelf-life indicated by the expiry date (4 years from manufacture date)*. The Pad-Pak must be replaced out if: If the status indicator on the SAM 300P is flashing red or not flashing you may need to replace the Pad-Pak. For diagnosis of the reason for the status indicator flashing red or not flashing please refer to the troubleshooting section of this manual.

HOW TO REPLACE A PAD-PAK(TM)

1.Take the replacement Pad-Pak(TM) from its protective bag. 2.Remove the old Pad-Pak(TM) which is to be replaced. 3.Follow the instruction for Pad-Pak(TM) installation which can be found on the page titled "Preparing your samaritan® PAD for use". 4. Push the Pad-Pak(TM) firmly to ensure it is fully inserted. 5.Check status indicator. If the Pad-Pak(TM) has been inserted correctly, status indicator flashes green approximately every 5 seconds. 6.Press the On/Off button to turn the device on. Listen for the appropriate messages to start. Press the On/Off button again to turn the device off. Ensure no warning messages are issued by the device and that the status indicator continues to flash GREEN once every five seconds. 7. If necessary inform relevant safety officer or person responsible for maintenance of the samaritan® PAD. 8. Update the relevant records to show the date that the replacement Pad-Pak(TM) was placed into service. 9.Dispose of the old Pad-Pak(TM).

PAD-PAK(TM) OR PEDIATRIC-PAK(TM). HeartSine Technologies have developed two versions of the Pad- Pak(TM). The standard Pad-Pak(TM) is intended to be used with suspected victims of SCA who are over eight years old or weigh more than 25kg (55lb). The Pediatric-Pak(TM) (child) is intended for us on suspected victims of SCA who are over one year old and less than eight years old weighing less than 25kg (55lb). The Pediatric-Pak(TM) is designed for use only in the samaritan® PAD SAM300P. HeartSine recommend that a samaritan® PAD sam300P is deployed in locations where emergency responses involving pediatric patients may occur. Contact your authorized distributor or HeartSine directly for further information. You must remember to check the expiration date on the Pad-Pak(TM)regularly. The Pad-Pak(TM) is a single use device with a stated expiry date. The expiry date is stated on the Pad-Pak(TM). The expiry date is given beside the symbol shown in the figure on the left here. Heartsine Samaritan Adult Pad-Pak Combined Electrode Battery Cartridge Integrated Unit expiration DateThe Pad-Pak(TM) has a warranty for use up until the date stated. The Pad- Pak(TM) should not be used beyond the stated expiry date. The Pad-Pak(TM) is a single use item. If a Pad-Pak(TM) is used on a patient they must not be used again. Check the expiration date of the Pad-Pak(TM) currently inserted into the samaritan® PAD. If the Pad-Pak(TM) has exceeded its use by date, remove it from the samaritan® PAD and replace with a new Pad-Pak(TM). Remove Pad-Pak(TM) from its packaging. Push Pad-Pak(TM) into the opening and listen for the "click" sound to ensure it is properly inserted. Place the samaritan® PAD into its Soft Carry Case. For alternative transport cases ask HeartSine or your distributor.

CHECK DEVICE is working optimally. PUSH the ON Button. Ensure you can hear the voice prompts: CALL for medical assistance Switch OFF by pressing the Button PAD-PAK(TM) INSTALLATION INSTALL 4 Put into a wall case or safe visible location. The Pad-Pak(TM) includes the battery and defibrillation electrodes in one cartridge. See expiry date for both on label. Place the samaritan® PAD and the Pad-Pak(TM)(TM) on a flat surface. Once the Pad-Pak(TM) is installed properly the PAD STATUS INDICATOR will begin to blink Green every 5 seconds. Do not open Pad-Pak(TM) tray or open defibrillation pads protective packaging until the time of emergency use when they are applied to a patient.

Price:   $176.00 