|
Your One-Stop Source for Lifepak
12 Defibrillator, Pads, Batteries & all
AED Accessorie...Click |
|
 Medtronic Physio-Control LIFEPAK 12 Defibrillator monitor fast patch connector edge system electrodes - 11996-000092
AED
Professionals™
General Medical Devices, Inc. Company
The Most Trusted Name In AED Defibrillator Supplies
AED Professionals is a Certified Authorized Medtronic Physio-Control
Dealer |
30 Day
Unconditional Money Back Guarantee
BBB Accredited Business |
Free Shipping
Shop with confidence
Authorized Direct Distributor
888-541-2337
.We
Accept Purchase Orders
 |
|
|
. |
Home |
LIFEPAK 12 Accessories |
LIFEPAK 12 Power Options |
LIFEPAK 12 Batteries |
LIFEPAK 12 Electrodes |
Contact Us
... |
....... .....
Emergency Oxygen
|
Resuscitators
|
Pocket Cpr Units
|
PO/GSA
Bids
|
View
Shopping Cart
... |
|

Original
Equipment Manufactured Accessories
Lifepak
12 Defibrillator/Monitor
EDGE System Electrodes
with FAST-PATCH Connector -
11996-000092
Must be used with QUIK-COMBO to
FAST -PATCH Adapter Cable.
(11110-000052) (Alternate P/N: 3011030)
|
Physio-Control LIFEPAK12 Defibrillator/ Monitor
EDGE System Electrodes
with FAST-PATCH Connector -
11996-000092
Must be used with QUIK-COMBO to
FAST -PATCH Adapter Cable.
(11110-000052 - see
below)
$21.00
|
Replacing and Removing Electrodes:
Replace QUIK-COMBO electrodes after 50 defibrillation shocks or 24
hours on the patient’s skin or 8 hours of continuous pacing.
To remove QUIK-COMBO or FAST-PATCH electrodes from the patient: 1
Slowly peel back the electrode from the edge, supporting the skin.
Removing
Therapy Electrodes from Skin
2 Clean and dry
the patient’s skin. 3 When replacing electrodes, adjust the
electrode positions slightly to help prevent skin burns. 4 Close the
protective cover on the QUIK-COMBO therapy cable connector when the
cable is not in use. In addition, disconnect the defibrillation
cable from the FAST-PATCH electrodes. 1 Press down around the
electrode post. 2 Pinch the snap connector with the fingers of the
other hand and pull straight up.
WARNING! Possible cable damage and ineffective energy delivery or
loss of monitoring.
Improper
disconnection of the defibrillation cable may damage the cable
wires. This can result in failure to deliver energy or loss of ECG
signal during patient care. Position the cable so that it will not
be pulled, snagged, or tripped over. Do not disconnect the
defibrillation cable snap connectors from electrode posts or posts
on testing devices by pulling on the cable. Disconnect the cable by
pulling
each cable
connector straight out.
Confidence in
Physio-Control LIFEPAK 12 Products
Unlike
some third party accessories, all of
Medtronic
Physio-Control LIFEPAK 12 replacement accessories,
including
Physio-Control LIFEPAK12 Defibrillator/ Monitor
EDGE System Electrodes with FAST-PATCH Connector -
11996-000092 are
tested and validated with LIFEPAK
devices by Physio-Control.
Original
Equipment Manufactured Accessories
Associated Accessories▼ |
Physio-Control LIFEPAK12 Defibrillator/ Monitor
EDGE System Electrodes with QUIK-COMBO
Connector
11996-000091
$37.00
►More Info |

Physio-Control LIFEPAK12 Defibrillator/ Monitor EDGE System Electrodes with QUIK-COMBO Connector and REDI-PAK™ Preconnect System
11996-000017
$42.00
►More Info
|

Physio-Control LIFEPAK12
Defibrillator/ Monitor
EDGE System RTS (Radiotransparent) Electrodes with QUIK-COMBO Connector
11996-000090
$45.00
►More Info
|

Physio-Control LIFEPAK12 Defibrillator/ Monitor Pediatric EDGE System RTS Electrodes with QUIK-COMBO Connector For use only on manual defibrillator/ monitors. 12-month minimum shelf life at time of shipment.
11996-000093
$45.00
►More Info |
|

FAST-PATCH® Adapter Cable
For use with the QUIK-COMBO therapy cable
for the
LIFEPAK 12 defibrillator/monitor.
11110-000052
(Alternate P/N: 3011030)
$231.00
|

QUIK-COMBO® Therapy Cable
For use with the
LIFEPAK 12 defibrillator/monitor.
11110-000040
$315.00 |
|
|
|
►For
More Accessories, Please
Click Here |
|
AED
Professionals™
Buy With Confidence
A
Better Business Bureau Accredited Business
Member
Chamber Of Commerce, Palatine, Illinois, U.S.A.
Member U.S. Woman's Chamber Of Commerce
Corporate Offices:
348
W. Colfax St., Palatine IL 60067
Phone: 1-847-202-3858
Fax: 1-866-879-7795. Toll Free: 1-888-541-2337
Copyright © 2003 - 2011 All rights of design and text
content
reserved
|