| Your One-Stop Source for Lifepak 12 Defibrillator, Pads, Batteries & all AED Accessorie...Click | ||||||
|
.
AED
Professionals™
30 Day
Unconditional Money Back Guarantee | ||||||
| . | ||||||
|
Home |
LIFEPAK 12 Accessories |
LIFEPAK 12 Power Options |
LIFEPAK 12 Batteries |
LIFEPAK 12 Electrodes |
Contact Us
... |
||||||
|
....... .....
Emergency Oxygen
|
Resuscitators
|
Pocket Cpr Units
|
PO/GSA
Bids
|
View
Shopping Cart
... |
||||||
|
.....
Lifepak
12 Defibrillator/Monitor
QUIK-COMBO with REDI-PAK™ pre-connect system Electrodes designed for patients weighing 15 kg (33 lbs) or more and allow pre-connection of the electrode set to the device while maintaining electrode shelf life and integrity. To help prevent electrode damage: • Do not fold the electrodes. • Do not trim the electrodes. • Do not crush, fold, or store the electrodes under heavy objects. • Store electrodes in a cool, dry location (59° to 95°F or 15° to 35°C). Electrode Placement: When using QUIK-COMBO or FAST-PATCH electrodes, make sure the electrodes: • Fit completely on the chest as described on page 3-4 or page 4-3. • Have at least one inch of space between electrodes. • Do not overlap bony prominences of sternum or spine. To place the electrodes: 1 Prepare the patient for electrode placement: • Remove all clothing from the patient’s chest. • Remove excessive chest hair as much as possible. Avoid nicking or cutting the skin if using a shaver or razor. If possible, avoid placing the electrodes over broken skin. • Clean and dry the skin. If there is ointment on the patient’s chest, use soap and water to clean the skin. Briskly wipe the skin dry with a towel or gauze. This mildly abrades the skin and removes oils, dirt, and other debris for better electrode adhesion to the skin. Do not use alcohol, tincture of benzoin, or antiperspirant to prep the skin. 2 Slowly peel back the protective liner on the electrodes, beginning with the cable connection end (see Figure 5-2). Figure 5-2 Peeling the Liner from the Electrode 3 Place the electrodes in the anterior-lateral or anterior-posterior position, as described on page 3-4 or page 4-3, depending on the therapy to be provided and special placement considerations. 4 Starting from one edge, firmly press the electrode on the patient’s chest to eliminate air pockets between the gel surface and the skin. Firmly press all adhesive edges to the skin. Note:Once applied, therapy electrodes should not be repositioned.
The LIFEPAK 12 defibrillator/monitor uses QUIK-COMBO® pacing/defibrillation/ECG electrodes or FAST-PATCH® disposable defibrillation/ECG electrodes for ECG monitoring and patient therapy. The therapy cable connects the QUIK-COMBO or FAST-PATCH electrodes to the defibrillator. For more information about QUIK-COMBO or FAST-PATCH electrodes, refer to the Operating Instructions of your LIFEPAK 12 manual. Confidence in Physio-Control LIFEPAK 12 Products Unlike some third party accessories, all of Physio-Control LIFEPAK 12 replacement accessories, including Physio-Control LIFEPAK12 Defibrillator/ Monitor EDGE System Electrodes with QUIK-COMBO Connector and REDI-PAK™ Preconnect System - 11996-000017 are tested and validated with LIFEPAK devices by Physio-Control.
Original
Equipment Manufactured Accessories |
||||||
Physio-Control LIFEPAK12 Defibrillator/ Monitor EDGE System Electrodes with QUIK-COMBO Connector 11996-000091 ►More Info |
|
|
|
|||
|
AED
Professionals™
|
||||||