Cardiac Science Powerheart G3 AED Pro Rechargeable Battery 9144-101
Free
Shipping
Powerheart G3 AED Pro Rechargeable Battery:
:.
..
Cardiac Science Powerheart G3 AED Pro Rechargeable Battery 9144-101, when used with the 9044-001 Battery Charger provides you a rechargeable battery solution for use in Powerheart AED G3 Pro models. Rechargeable Battery warranty is full 1-year
Cardiac Science Powerheart G3 AED Pro Rechargeable Battery 9144-101 technical specifications:
Attachment Method: Snaps into AED
Color:Yellow
For Use With: Powerheart AED G3 Pro
Special notes: Disposable. Please dispose Cardiac Science Powerheart G3 AED Pro
rechargeable according
to battery disposable protocols.
Package Contents: 1 battery
Packaging: Bag
Weight: 1.65 lbs
|

Cardiac Science Powerheart G3 AED Pro Battery Charger 9044-001
Free
Shipping
Cardiac Science Powerheart G3 AED Pro Battery Charger 9044-001:
:.
..
This charger will recharge the 9144 battery for the G3 Pro to full capacity. This battery charger works with the 9144 rechargeable battery to provide you with a rechargeable battery solution for your Powerheart AED G3 Pro. For use with 9144-101 battery for the Powerheart G3 Pro
Cardiac Science Powerheart G3 AED Pro Battery
Charger 9044-001 technical specifications:
Attachment Method:
Plugs into battery
Color:
Black
For Use With:
Powerheart AED G3 Pro
Notes:
Reusable
Package Contents:
1 battery charger, power cable
Packaging:
Bag
Weight:
1.5 lbs
|
Other Accessories you may need▼

Cardiac Science Powerheart Adult Defibrillation Electrode Pads 9131-001
Cardiac Science Powerheart Adult Defibrillation
Electrode Pads 9131-001 :
:.
..
Getting Started: Cardiac Science Powerheart Adult Defibrillation Electrode Pads come in a ready-to-use, sealed package containing
one pair of self-adhesive pads with an attached cable and connector. The
pads are disposable and should be discarded after each rescue.
The pads have a limited shelf life and should not be used beyond the
expiration date. Keep a fresh, unopened pair of pads plugged into the AED
at all times. Refer to the pad package label for operation temperatures.
An audible and visual alert will indicate after the self-test if the pads are missing, unplugged or damaged.
PAD INSTALLATION
1. Open the lid of the Cardiac Science Powerheart G3 AED.
2. Place the pad package into the lid so that the expiration label is visible through the
clear window on the lid. The expiration date of the pads will then be readable
without opening the lid of the AED.
3. Match the color of the connectors (red to red), then plug the pad connector into the
AED case. Once the pad connector is plugged into AED, the PAD indicator should extinguish.
4. Tuck the excess cable length in the bottom holder. With the pad package completely secured to the AED lid, close the lid.
5. Make sure the expiration date is visible through the clear window of the lid and check
to make sure that the STATUS INDICATOR is GREEN. If the pads are not installed
properly, the STATUS INDICATOR will be RED; call Customer Service for assistance.
CAUTION: Use only Cardiac Science Approved Equipment
Using batteries, pads, cables, or optional equipment other than those approved by
Cardiac Science may cause the AED to function improperly during a rescue.
CAUTION: Possible Improper AED Performance
Using pads that are damaged or expired may result in improper AED performance.
DIRECTIONS FOR USE:
1. Do NOT open until ready to use, short term use only.
2. Ensure the skin site is clean and dry.
3. Separate one pad from liner.
4. Place one pad on skin in either location.
5. Peel and place remaining pad.
STEP 1: ASSESSMENT AND PAD PLACEMENT
PREPARATION
Determine that the patient is over 8 years of age or weighs more than 55 pounds (25 kg) and exhibits
the following:
The patient is unresponsive, and
the patient is not breathing.
Remove clothing from the patient’s chest. Ensure the skin site is clean and dry. Dry the patient’s chest and
shave excessive hair if necessary.
Open the AED lid and wait until the LEDs are lit.
Note: When the patient is a child under 8 years of age or weighs less than 55 lbs (25kg), the
AED should be used with the Model 9730 Pediatric Attenuated Defibrillation Pads. Therapy
should not be delayed to determine the patient’s exact age or weight. See the directions for use
accompanying pediatric pads for procedure on changing adult pads to pediatric.
PLACE PADS
The AED will issue the prompt “Tear Open Package and Remove Pads.” Keep the pads connected to the
AED, tear the pad package along the dotted line and remove the pads from the package. Leave the package
attached to the pad wires.
After the prompt “Peel One Pad From Plastic Liner,” with a firm, steady
pull, carefully peel one pad away from the plastic liner.
Then, after the prompt “Place One Pad on Bare Upper Chest,” place the
pad with the sticky side of on the patient’s skin on the upper right chest,
placing the top of the pad on the collarbone. Avoid placing the pad
directly over the sternum.
Finally, after the prompt “Peel Second Pad and Place on Bare Lower Chest
As Shown,” pull the second pad from the plastic liner and place it on
the lower left chest, below and left of the breast.
Note: Cardiac Science’s defibrillation pads are non-polarized and can be placed in
either position as shown on the pad package.
When the pads are placed, the voice prompt will say “Do not touch patient. Analyzing Rhythm.” If the pads are
not properly placed or become disconnected at any time during the rescue, the voice prompt “Check Pads”
will be heard. When this occurs, ensure that:
Pads are firmly placed on clean, dry skin
Pad cable is securely plugged into the
AED.
|

Cardiac Science Powerheart AED G3 Pediatric Electrode Pads 9730-002
Free
Shipping
Cardiac Science Powerheart AED Pediatric Pads::.
..
Cardiac Science Pediatric Defibrillation Electrode Pads 9730-002 should be used when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight. See the directions for use accompanying Pediatric Defibrillation Electrode Pads # 9730-002 for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|

Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001
Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001::.
..
These infant / child reusable training defibrillation pads allow you to simulate hands-on pediatric rescue scenarios with the Powerheart G3. Pediatric Training Defibrillation Pads 9725-001 are intended for use with Cardiac Science AED training device to simulate and practice a real-life rescue scenario.
These are intended for use with with Powerheart® AED G3 Trainer.
Cardiac Science Pediatric, infant / child Training
Electrode Pads, teach how to use the
defibrillation pads when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight
when performing a real-life rescue. See the directions for use accompanying Pediatric Defibrillation Electrode Pads for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|
AED ProfessionalsTM General Medical Devices, Inc. Company
Member Chamber
Of Commerce, Palatine, Illinois, U.S.A.
Member U.S. Woman's Chamber Of Commerce Corporate Office: 348
W. Colfax Street, Palatine IL 60067
Phone: 1-847-202-3858
Fax: 1-866-879-7795 Toll Free: 1-888-541-2337
Copyright © 2004 - 2012 All rights
of design and text reserved
AED
Professionals is AED and AED Accessories Wholesale and Retail Store
of Super Defibrillator Values
AED Professionalsè
Copy Righted: ©Quick-Start
Package
AED ProfessionalsèCopy
Righted:
©Quick-Start
Essentials
Package
AED Defibrillators
ECG/EKG Machines
Patient
Monitors
Oximeters
Stress Test Systems
Portable
X-Ray Units AED Cabinets
Your One-Stop Source
for all Automatic External Defibrillator, Pads, Batteries & all
Accessories
|
|