Cardiac Science Powerheart Polarized Adult Defibrillation Electrode Pads
9660-001
:.
..
Cardiac Science Powerheart G3 Polarized AED Defibrillation Electrodes Adult Pads Part No. 9660-001 are polarized and are intended for use by trained medical responders in conjunction with the Powerheart AED G3 Pro but will work with all current Powerheart AEDs
Polarized AED Defibrillation Electrodes Adult Pads:
1. Open the lid of the Cardiac Science Powerheart G3 AED.
2. Place the pad package into the lid so that the expiration label is visible through the
clear window on the lid. The expiration date of the pads will then be readable
without opening the lid of the AED.
3. Match the color of the connectors (red to red), then plug the pad connector into the
AED case. Once the pad connector is plugged into AED, the PAD indicator should extinguish.
4. Tuck the excess cable length in the bottom holder. With the pad package completely secured to the AED lid, close the lid.
5. Make sure the expiration date is visible through the clear window of the lid and check
to make sure that the STATUS INDICATOR is GREEN. If the pads are not installed
properly, the STATUS INDICATOR will be RED; call Customer Service for assistance.
CAUTION: Use only Cardiac Science Approved Equipment
Using batteries, pads, cables, or optional equipment other than those approved by
Cardiac Science may cause the AED to function improperly during a rescue.
CAUTION: Possible Improper AED Performance
Using pads that are damaged or expired may result in improper AED performance.
DIRECTIONS FOR USE:
1. Do NOT open until ready to use, short term use only.
2. Ensure the skin site is clean and dry.
3. Separate one pad from liner.
4. Place one pad on skin in either location.
5. Peel and place remaining pad.
STEP 1: ASSESSMENT AND PAD PLACEMENT
PREPARATION:
Determine that the patient is over 8 years of age or weighs more than 55 pounds (25 kg) and exhibits
the following:
The patient is unresponsive, and
the patient is not breathing.
Remove clothing from the patient’s chest. Ensure the skin site is clean and dry. Dry the patient’s chest and
shave excessive hair if necessary.
Open the AED lid and wait until the LEDs are lit.
Note: When the patient is a child under 8 years of age or weighs less than 55 lbs (25kg), the
AED should be used with the Model 9730 Pediatric Attenuated Defibrillation Pads. Therapy
should not be delayed to determine the patient’s exact age or weight. See the directions for use
accompanying pediatric pads for procedure on changing adult pads to pediatric.
PLACE PADS
The AED will issue the prompt “Tear Open Package and Remove Pads.” Keep the pads connected to the
AED, tear the pad package along the dotted line and remove the pads from the package. Leave the package
attached to the pad wires.
After the prompt “Peel One Pad From Plastic Liner,” with a firm, steady
pull, carefully peel one pad away from the plastic liner.
Then, after the prompt “Place One Pad on Bare Upper Chest,” place the
pad with the sticky side of on the patient’s skin on the upper right chest,
placing the top of the pad on the collarbone. Avoid placing the pad
directly over the sternum.
Finally, after the prompt “Peel Second Pad and Place on Bare Lower Chest
As Shown,” pull the second pad from the plastic liner and place it on
the lower left chest, below and left of the breast.
Note: Cardiac Science’s defibrillation pads are non-polarized and can be placed in
either position as shown on the pad package.
When the pads are placed, the voice prompt will say “Do not touch patient. Analyzing Rhythm.” If the pads are
not properly placed or become disconnected at any time during the rescue, the voice prompt “Check Pads”
will be heard. When this occurs, ensure that:
Pads are firmly placed on clean, dry skin
Pad cable is securely plugged into the AED.
|

Cardiac Science Powerheart Adult Defibrillation Electrode Pads 9131-001
Cardiac Science Powerheart Adult Defibrillation
Electrode Pads 9131-001 :
:.
..
Cardiac Science Powerheart Adult Defibrillation Electrode Pads come in a ready-to-use, sealed package containing
one pair of self-adhesive pads with an attached cable and connector. The
pads are disposable and should be discarded after each rescue.
The pads have a limited shelf life and should not be used beyond the
expiration date. Keep a fresh, unopened pair of pads plugged into the AED
at all times. Refer to the pad package label for operation temperatures.
An audible and visual alert will indicate after the self-test if the pads are missing, unplugged or damaged.
ADULT DEFIBRILLATION ELECTRODE INSTALLATION:
1. Open the lid of the Cardiac Science Powerheart G3 AED.
2. Place the pad package into the lid so that the expiration label is visible through the
clear window on the lid. The expiration date of the pads will then be readable
without opening the lid of the AED.
3. Match the color of the connectors (red to red), then plug the pad connector into the
AED case. Once the pad connector is plugged into AED, the PAD indicator should extinguish.
4. Tuck the excess cable length in the bottom holder. With the pad package completely secured to the AED lid, close the lid.
5. Make sure the expiration date is visible through the clear window of the lid and check
to make sure that the STATUS INDICATOR is GREEN. If the pads are not installed
properly, the STATUS INDICATOR will be RED; call Customer Service for assistance.
CAUTION: Use only Cardiac Science Approved Equipment
Using batteries, pads, cables, or optional equipment other than those approved by
Cardiac Science may cause the AED to function improperly during a rescue.
CAUTION: Possible Improper AED Performance
Using pads that are damaged or expired may result in improper AED performance.
DIRECTIONS FOR USE:
1. Do NOT open until ready to use, short term use only.
2. Ensure the skin site is clean and dry.
3. Separate one pad from liner.
4. Place one pad on skin in either location.
5. Peel and place remaining pad.
STEP 1: ASSESSMENT AND PAD PLACEMENT
PREPARATION:
Determine that the patient is over 8 years of age or weighs more than 55 pounds (25 kg) and exhibits
the following:
The patient is unresponsive, and
the patient is not breathing.
Remove clothing from the patient’s chest. Ensure the skin site is clean and dry. Dry the patient’s chest and
shave excessive hair if necessary.
Open the AED lid and wait until the LEDs are lit.
Note: When the patient is a child under 8 years of age or weighs less than 55 lbs (25kg), the
AED should be used with the Model 9730 Pediatric Attenuated Defibrillation Pads. Therapy
should not be delayed to determine the patient’s exact age or weight. See the directions for use
accompanying pediatric pads for procedure on changing adult pads to pediatric.
PLACE PADS
The AED will issue the prompt “Tear Open Package and Remove Pads.” Keep the pads connected to the
AED, tear the pad package along the dotted line and remove the pads from the package. Leave the package
attached to the pad wires.
After the prompt “Peel One Pad From Plastic Liner,” with a firm, steady
pull, carefully peel one pad away from the plastic liner.
Then, after the prompt “Place One Pad on Bare Upper Chest,” place the
pad with the sticky side of on the patient’s skin on the upper right chest,
placing the top of the pad on the collarbone. Avoid placing the pad
directly over the sternum.
Finally, after the prompt “Peel Second Pad and Place on Bare Lower Chest
As Shown,” pull the second pad from the plastic liner and place it on
the lower left chest, below and left of the breast.
Note: Cardiac Science’s defibrillation pads are non-polarized and can be placed in
either position as shown on the pad package.
When the pads are placed, the voice prompt will say “Do not touch patient. Analyzing Rhythm.” If the pads are
not properly placed or become disconnected at any time during the rescue, the voice prompt “Check Pads”
will be heard. When this occurs, ensure that:
Pads are firmly placed on clean, dry skin
Pad cable is securely plugged into the AED.
Associated Item:▼

Cardiac Science Powerheart AED G3 Pediatric Electrode Pads 9730-002
Free
Shipping
Cardiac Science Powerheart AED Pediatric Pads::.
..
Cardiac Science Pediatric Defibrillation Electrode Pads 9730-002 should be used when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight. See the directions for use accompanying Pediatric Defibrillation Electrode Pads # 9730-002 for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|
Associated Item:▼

Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001
Cardiac Science Pediatric Training AED Defibrillation Electrode Pads 9725-001::.
..
These infant / child reusable training defibrillation pads allow you to simulate hands-on pediatric rescue scenarios with the Powerheart G3. Pediatric Training Defibrillation Pads 9725-001 are intended for use with Cardiac Science AED training device to simulate and practice a real-life rescue scenario.
These are intended for use with with Powerheart® AED G3 Trainer.
Cardiac Science Pediatric, infant / child Training
Electrode Pads, teach how to use the
defibrillation pads when the patient is a child under 8 years of age or weighs less than 55 lbs. However, therapy should not be delayed to determine the patient’s exact age or weight
when performing a real-life rescue. See the directions for use accompanying Pediatric Defibrillation Electrode Pads for procedure on changing adult pads to pediatric.
These reduced-energy child/pediatric defibrillation pads work with all 9200 and 9300 series AEDs, enabling rescuers to provide defibrillation therapy to children who are less than 8 years of age or who weigh less than 55 pounds.
|
Associated Item:▼

Powerheart G3 Nonrechargeable
AED Battery Yellow 9146-202
Free
Shipping
Cardiac Science Powerheart G3 Intellisense Lithium Battery: :.
..
Cardiac Science Powerheart G3 Intellisense Lithium Battery w/ 4-year warranty. Use in G3 9300E, 9300A, 9390E, and 9390A devices made after April 12, 2004. This Intellisense Lithium Battery 9146-202 is for use in yellow colored Powerheart® AED. The Cardiac Science IntelliSense
battery technology offers you the most advanced
battery capabilities available for
defibrillators. Cardiac Science IntelliSense
batteries contain an integrated memory chip that
automatically stores important usage
information, enabling the battery to maintain a
complete history of its operating life. The
actual battery history can be reviewed using the RescueLink
software.
|
|
. |
. |
. |
AED ProfessionalsTM General Medical Devices, Inc. Company Corporate Office: 348
W. Colfax Street, Palatine IL 60067
Phone: 1-847-202-3858
Fax: 1-866-879-7795 Toll Free: 1-888-541-2337
Copyright © 2004 - 2010 All rights
of design and text reserved